CEE controls fail heat and building-system jobs touching warehouses
BAT-TH-116, BAT-TH-162, BAT-TH-163 and BAT-TH-164 operations fail on-site or contact checks where logistics warehouses, reserves or storage premises are involved, even partly.
Af Taxxa AI OyOffentliggjort 28. november 2026
Branche: På tværs af brancher
A building-management-system operation under fiche BAT-TH-116 fails the on-site control where the operation concerns, even partly, logistics warehouses, reserves, warehouses (refrigerated or not) or storage premises.Legifrance The contact check verifies the exclusion of those premises alongside the existence of an installed or improved gestion technique du bâtiment system, the building's activity sector — bureaux, enseignement, commerces, hôtellerie-restauration, santé — and the absence of manifest poor workmanship reported by the beneficiary; any gap on a checked point makes the control non satisfaisant. The inspection body leaves surfaces of that warehouse type out of the managed surfaces it counts for the certificate amount, reporting the climate zone, the activity sector and the managed surface per use, and a measured heating-use surface gap of more than 10% against the attestation sur l'honneur fails the operation outside outre-mer, as does a cooling-use gap of more than 10% in outre-mer.
For geothermal operations, the BC criteria fail a BAT-TH-162 operation where it concerns, even partly, the same logistics warehouses, reserves, warehouses or storage premisesLegifrance, and the contact check verifies that exclusion alongside the existence of an installed geothermal system. The on-site list fails operations where the beneficiary attests in writing to missing engagement or completion proofs, where the proof or the manufacturer's document lacks the mentions required by the fiche, where the installed system or its heat pumps do not match the proof, where the equipment is not a geothermal system or lacks the full capture, production and regulation chain, and where a heat pump falls outside eau/eau on shallow aquifers below 200 metres or eau glycolée/eau on boreholes. Domestic-hot-water-only use, network connections, COP or Etas mismatches and performance below fiche values also fail. The inspection report states the heated surface for BAT-TH-162 or the number of heated dwellings for BAR-TH-178, the climate zone, the boiler power after works and, per heat pump, the rated thermal power, the uses covered and the Etas or COP; a declared-minus-measured heated-surface gap above 10% fails BAT-TH-162.
For heat-pump operations, the BD criteria fail BAT-TH-163 and BAT-TH-164 operations involving, even partly, logistics warehouses, reserves, warehouses or storage premisesLegifrance, with the same contact-check exclusion and the same non-satisfying result on any gap. The report states the heated surface for BAT-TH-163 and BAT-TH-164 or the heated dwelling count for BAR-TH-179 and BAR-TH-180, the climate zone, the boiler power after works and per-pump rated power, uses and Etas or COP. Equipment that is not air/eau under BAR-TH-179 or BAT-TH-163, or not eau/eau or eau glycolée/eau under BAR-TH-180 or BAT-TH-164, heat pumps installed only for domestic hot water, declared or actual COP/Etas shortfalls against the fiche, a missing or non-compliant prior dimensioning study and defects in emitters or hydraulic and refrigeration networks all fail the on-site control.
Each on-site control in these sections runs on the operation site after completion, on visible and accessible parts, without destructive sampling or coring, while the same sections set contact checks on the installed works and the manifest defects declared by the beneficiary, and any manifest poor workmanship calling the installed equipment's performance, durability or safety into question fails the operation. The Coup de pouce heating criteria in both lists fail operations whose completion proof omits the removed equipment's fuel and type or an applicable derogation. These premises exclusions therefore run across the GTB (BAT-TH-116), geothermal (BAT-TH-162) and heat-pump (BAT-TH-163 and BAT-TH-164) operations.Legifrance
Legal basis: arrêté du 28 septembre 2021 relatif aux contrôles dans le cadre du dispositif des certificats d'économies d'énergie, parts AK, BC and BD; fiches BAT-TH-116, BAT-TH-162, BAT-TH-163, BAT-TH-164, BAR-TH-178, BAR-TH-179 and BAR-TH-180.
Screen every BAT-TH-116, BAT-TH-162, BAT-TH-163 and BAT-TH-164 file for warehouse, reserve or storage-premises surfaces and route those parts out of the CEE scope before the control.